Thomas & Betts
Press Room
Sales Partner Login
      Joslyn Hi-Voltage manufactures power transmission and distribution equipment for electric utilities - reclosers
     
Universal Vac-RupterÒ Interrupter


Click on photo for graphical representation


The Joslyn Universal Vac-RupterÒ Interrupter (UVI) converts an isolating switch into a load interrupter switch. The Vac-Rupter allows the switch to be used for full load interruption up to 34.5kV or for the reduced recovery voltage application of loop splitting or parallel switching up to 230kV depending upon system voltage, grounding considerations of the system and load, and the characteristics of the load.

Universal Vac-Rupters can be quickly mounted on most types of group operated isolating switches of all manufacturers. Conversion of an existing air switch is easily achieved since no special tools or training is required. Procedures are simple for installing the interrupter, fixed and moving arc horns, and verifying proper operation. Adding a Vac-Rupter will not affect the mechanical operation of the switch.

The UVI can also be applied for line dropping and cable switching at system voltages to 25kV, but can be extended to 72.5kV with the Voltage Limiter attachment.

UVI Interrupter Attachments Brochure
UVI interrupter attachments instructions
Interrupter Application Guide

Maintenance-Free
  Long life of 5,000 operations.
Ease of Installation
  Three phase sets can be installed quickly and easily in approximately 4 hours.
Rugged Construction
  Anodized aluminum mechanism housing protects against corrosive action and sealed vacuum interrupter chamber is sealed against moisture, ultraviolet activity, and contamination - no SF-6 gas or oil is used.
Safe Interruption
  Interruption is noiseless and liberates no hot exhaust or ionized gases.
Proven Performance
  Installations of more than 35 years demonstrate the reliability and proven performance of the interrupter.
Air Switch Ratings Unaffected
  The continuous, momentary, and impulse ratings of the switch are unaffected since the UVI is in the power circuit for a few seconds.
        
  
UVI Ratings
Application
System Voltage
(kV)
Interrupting
Capability
(Amperes)
(at peak recovery
voltage of 30 kV)
Loop Splitting/Parallel Switching
230 kV 2000
Load Switching
Grounded & Ungrounded
Grounded Only

25 kV
34.5 kV
2000
Capacitor Switching
Grounded & Ungrounded
Grounded Only

15 kV
25 kV
800
140
Reactor Switching
25 kV 2000
Transformer Magnetizing Switching
25 kV 2000
Line Dropping
25 kV
72.5 kV*
140
15*
Cable Switching
25 kV
72.5 kV*
800
15*
* with Voltage Limiter Attachment

Ordering Information
1 Specify air switch manufacturer
2 Supply switch model number
3 Specify voltage and current rating
4 Indicate size of insulator bolt circle
5 Describe blade movement including clockwise or counter clockwise rotation as viewed
from hinge end
6 Specify application, system voltage and grounding
  

Joslyn Hi-Voltage Royce Thompson Fisher Pierce

Home | About Us | Products | Library | Contact Us

Joslyn Hi-Voltage - 4000 E 116th Street, Cleveland, Ohio 44105 USA   Email: T&B Contact Information
Copyright © 2001 Joslyn Hi-Voltage. All rights reserved.
   